CE Marked - Available Globally
Dymax BlueWave® 200 version 3.1 is a high-intensity, light-curing spot-lamp system. This unit emits energy in the UVA and visible portion of the spectrum (300-450 nm) for light curing of adhesives, coatings, and encapsulants. Ideally suited for either manual or automated processes, the system contains an integral shutter which can be actuated by a foot pedal or PLC and a universal power input that provides consistent performance at any voltage. A wide range of light guides in various materials and configurations are available for use with this spot-curing unit, providing application flexibility.
The faceplate design of the BlueWave® 200 V3.1 has an operator interface with an easy-to-read LCD display and patented intensity adjustment control. The control is important for validating an appropriate intensity range and maintaining that range during production. Intensity measurement is easily accomplished with the Dymax ACCU-CAL™ 50 radiometer. Scheduled intensity measurements taken during the production process will indicate whether additional intensity adjustments are required. This method of measurement provides the most accurate readings as they are taken through the lightguide in the actual production setting.
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchLooking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchBuild a complete solution or find replacement parts for your project
Limited quantities, please submit RFQ for pricing and availability.
Unit with No Power Cord*
*The appropriate power cord is included for orders in Europe.
Asian Version (Type G Plug)
North American Version (115V Standard Plug)
Clearance - BlueWave 200 V3.1 | North American Version (115V Standard Plug)
Limited quantities, please submit RFQ for pricing and availability.
Clearance - BlueWave 200 V3.1 | North American Version (115V Standard Plug)
Limited quantities, please submit RFQ for pricing and availability.
ACCU-CAL™ 50 for Spot and Flood Lamps and Conveyors: Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case)
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
200 Watt UV Bulb & Reflector Assembly
Two pole, liquid-filled lightguide, 3 mm x 1M
Three pole, liquid-filled lightguide, 3 mm x 1M
Four pole, Fiber Optic Lightguide, 3 mm x 1M
Lightguide adapter conversion kit (part #42932 listed under accessories) is required for use with serial numbers lower than 1000
Lightguide adapter conversion kit (part #60514 listed under accessories) is required for use with serial numbers at 1000 or higher
Single pole, liquid-filled lightguide, 5 mm x 1M
Single pole, liquid-filled lightguide, 5 mm x 1.5M
Single pole, liquid-filled lightguide, 8 mm x 1M (required to use a rod lens)
Compatible with: BlueWave® 75, BlueWave 200, BlueWave LED Prime UVA, BlueWave LED VisiCure®, BlueWave DX-1000, BlueWave DX-1000 VisiCure®
Clearance - Three pole, liquid-filled lightguide, 3 mm x 1M
Limited quantities, please submit RFQ for pricing and availability.